DefaultANIScreenInd |
|
Description |
Allows you to set the type of Screening Indicator messaging sent by the Tenor for this signaling group. There is a command with the same name in the IPRG and ISDNSG. See the links below. |
|
Guidelines |
The SS7 Signaling Group prompt is only available for Tenor CMS, code version P103-00-00 or later. Valid settings are as follows:
Values 1 and 3 may not be available for all countries. |
|
Related Topics |
SS7SignalingGroup-1 (ss7sg 1) Prompt Commands DefaultANIPresentationInd - SS7 Signaling Group |
|
Location |
Circuit Configuration > Signaling Configuration > SS7 Signaling Groups > SS7 Signaling Group-n > Default ANI Screen Indicator |
|
Options |
Select from the drop-down box. Options are as follows:
|
|
Cmd Type |
Command |
|
Prompt Level |
config-SS7SignalingGroup-1# |
|
Syntax |
set defaultaniscreenind ordanisi { 0 | 1 | 2 | 3 | 4 } |
|
Arguments |
0 Pass-through whatever is received on the inbound leg 1 User-provided, not screened 2 User-provided, verified and passed 3 User-provided, verified and failed 4 Network-provided |
|
Default |
0 Pass-through whatever is received on the inbound leg |
|
Examples |
config-SS7SignalingGroup-1# set danisi 2 Sets the Screening Indicator message to be User-provided, verified and passed. |