DefaultANIScreenInd

   
 

Description

Allows you to set the type of Screening Indicator messaging sent by the Tenor for this signaling group.

There is a command with the same name in the IPRG and ISDNSG. See the links below.

Guidelines

The SS7 Signaling Group prompt is only available for Tenor CMS, code version P103-00-00 or later.

Valid settings are as follows:

  • 0 - Pass-through whatever is received on the inbound leg (default)

  • 1 - User-provided, not screened

  • 2 - User-provided, verified and passed

  • 3 - User-provided, verified and failed

  • 4 - Network-provided

Values 1 and 3 may not be available for all countries.

Related Topics

SS7SignalingGroup-1 (ss7sg 1) Prompt Commands

DefaultANIPresentationInd - SS7 Signaling Group

DefaultANIScreenInd - IP Routing Group

DefaultANIScreenInd - ISDN Signaling Group

Configuration Manager

Location

Circuit Configuration > Signaling Configuration > SS7 Signaling Groups > SS7 Signaling Group-n > Default ANI Screen Indicator

Options

Select from the drop-down box. Options are as follows:

  • Pass-through whatever is received on the inbound leg

  • User-provided, not screened

  • User-provided, verified and passed

  • User-provided, verified and failed

  • Network-provided

Command Line

Cmd Type

Command

Prompt Level

config-SS7SignalingGroup-1# 

Syntax

set defaultaniscreenind ordanisi { 0 | 1 | 2 | 3 | 4 }

Arguments

0   Pass-through whatever is received on the inbound leg

1   User-provided, not screened

2   User-provided, verified and passed

3   User-provided, verified and failed

4   Network-provided

Default

0   Pass-through whatever is received on the inbound leg

Examples

config-SS7SignalingGroup-1# set danisi 2