LocalLoopType |
|
Description |
This command is for Analog Tenors set to Loop Start only. It allows you to configure the Tenor's FXO port to avoid an impedance mismatch with the phone line resulting in ERL (Echo Return Loss).You can determine the best local loop type based on the following test of the phone line. Type this command at the CLI: config-CASSignalingGroup-line# cmd test t <line#> <impedance> where line # is the number of the analog PSTN line of the Tenor, and impedance is the setting of the Impedance parameter for that line (see link below). The output of this command will give you a recommendation for the LLT parameter. |
|
Guidelines |
This setting is for CASSG-line; it is only exposed when ORientation=0 (line-side only). Valid settings are as follows:
|
|
Related Topics |
|
Location |
Circuit Configuration > Signaling Configuration > CAS Signaling Groups > CAS Signaling Group-n > Analog Specific tab > Local Loop Type |
|
Options |
Select an option from the dropdown box. Valid options are as follows:
|
|
Cmd Type |
Command |
|
Prompt Level |
config-CASSignalingGroup-line# |
|
Syntax |
set locallooptype or llt { 0 | 1 | 2 | 3 \ 4 | 5 | 6 | 7 } |
|
Arguments |
0 Type 0 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 7 Type 7 |
|
Default |
0 Type 0 |
|
Examples |
config-CASSignalingGroup-line# set llt 2 Sets the Local Loop Type to EIA Type 2. |